Municipal Wastewater Treatment Plant

A successful application on municipal wastewater treatment.

Contact us today for a free consultation.

Project Description

Siyang County is under the administration of Suqian, Jiangsu province, China. It borders the prefecture-level city of Huai’an to the southeast. Area is about 547 mi², with population of 831,112 (2010).

The effluent of wastewater treatment plant meets China National Class 1-A Discharge Requirement, with COD < 50 mg/L and NH3-N < 1 mg/L at all time.

Project Details

Client Siyang County, Jiangsu, China
Completion Date 2007
Treatment Capacity 50,000 m³/d (13,200,000 GPD)
Process Flow Two Phase Grids + Grit Chamber + BDP Basin +UV Disinfection
Key Words Municipal Wastewater, Sewage

Parameters and Facts

  • CODCr 60~340 mg / L
  • BOD5 30~120 mg / L
  • TSS about 180 mg / L
  • TN 30~50 mg / L
  • NH3-N 25~35 mg / L
  • TP 3~5 mg / L
  • CODCr about 45 mg / L
  • BOD5 6~8 mg / L
  • TSS about 10 mg / L
  • TN 10~15 mg / L
  • NH3-N about 1 mg / L
  • TP about 0.5 mg / L
  • Blueprint Area (m2/m3 ) 0.4~0.5
  • Operating Cost 0.12~0.17 CHY/Ton
  • Dissolved Oxygen 0.3 mg/L
  • Gas-Water Ratio 3~4
  • Sludge Concentration 6 – 8 g/L
  • Effective Depth of Water 5.5~6 m
  • Temperature 7 °C

 

 

Interested in BDP Technology?

Contact us for a free consultation, or explore more reference projects.

NEWSLETTER SIGN UP

Sign up for the BDP EnviroTech Newsletter.

Stay informed about ongoing BDP projects, events and company announcements, and get useful tips to help you reduce operating and discharge costs at your wastewater treatment operation.

5 + 8 =